The 2San 3-in-1 test checks for COVID-19, Flu A, and Flu B with one simple test, delivering results in just 10 minutes. Made in the USA, it features a familiar cassette design and a practical tube holder built into the carton for easy, hands-free testing.
A quick, convenient way to understand symptoms and get the right care fast—especially helpful for families with sick children at home.
Directions
PREPARING FOR THE TEST
NOTE: Do not open the test materials until ready for use. If the test cassette is open for an hour or longer, invalid test results may occur.

Check the expiration date of the test printed on the outer box.
Ensure all test components are at room temperature (15-30℃/59-86℉) before use.

WASH your hands with soap and water for 20 seconds or use hand sanitizer and dry them thoroughly.

LOCATE the tube holder on the box (look for the orange circle on the box).

a) INSERT the buffer tube into the tube holder. Ensure that the buffer tube is stable and upright. b) REMOVE the large cap from the buffer tube and set it aside for later use.

REMOVE test cassette from sealed pouch and lay it on a flat surface.
SAMPLE COLLECTION

REMOVE the swab from the pouch.
Be careful not to touch the swab tip (soft end) with hand.

CAREFULLY INSERT the swab no more than 3/4 inch (1.5 cm) into the nostril. Slowly rotate the swab at least 5 times against the nostril wall.
Do not insert the swab any further if you feel any resistance.

REMOVE the swab and repeat in the other nostril using the same swab. Check: Did you swab BOTH nostrils?
Note: If you are swabbing others, please wear a face mask. With children, the maximum depth of insertion into the nostril may be less than ½ to ¾ of an inch, and you may require another adult to hold the child’s head while swabbing.
Note: Failure to swab properly may cause false negative results.
RUNNING THE TEST

IMMERSE the swab into the buffer tube, and ensure it is touching the bottom of the TUBE and SWIRL the swab in the buffer. Ensure the sample is mixed thoroughly by making at least 10 circles.
Sample must be adequately mixed into the buffer, otherwise, incorrect results may occur.

LEAVE the swab in the buffer tube for 1 minute. A timer is recommended for this step.

After 1 minute, PINCH the tip of the swab from the outside of the tube to remove any excess liquid from the swab.
REMOVE and DISCARD the swab.

a) HOLD the buffer tube upright and SCREW the large cap back onto the tube. Ensure a tight fit to prevent leaking. b) TWIST to open the small cap at the top of the tube.

INVERT the buffer tube and SQUEEZE 4 drops of test sample into the sample well on the test cassette. Then DISCARD the buffer tube.
Note: Incorrect results may be observed if <4 drops of sample are added.
Sample must be applied to the test cassette within one hour of completing step 9.

START timer. Read results at 10 minutes.
Do not interpret results before 10 minutes or after 20 minutes. Inaccurate test interpretations may occur.
INTERPRETATION OF RESULTS
Look for lines next to ‘C’(Control), ‘F-A’, ‘F-B’ and ‘CoV’.
C = Control Line F-A = Flu A Test Line F-B = Flu B Test Line CoV = COVID-19 Test Line
A red line should always appear at the ‘C’ position; this is a control line and signals that the test is working properly.
INVALID RESULT

Check to see if a pink to red line is visible at the control line ‘C’ in the results window. If a line is not visible at ‘C’, even if any other line is visible in the results window, the result is considered invalid.
If you do not see a C line, DO NOT CONTINUE reading the results. It means your test is invalid. Repeat the test with a new sample and new test kit materials.
NEGATIVE RESULT

If a control ‘C’ line is visible and you do not see a line at ‘F-A’, ‘F-B’ or ‘CoV’, it means the test is negative. The Flu A, Flu B or COVID-19 virus have not been detected. If respiratory symptoms persist, you should seek follow-up care with your healthcare provider.
POSITIVE RESULT

If the control line at ‘C’ is visible and any other line or multiple lines on ‘F-A’, ‘F-B’ and/or ‘CoV’ are visible, the test is positive for that virus.
NOTE: Any pink to red test line, no matter how faint, should be considered a positive result when the control line is also present.
UNDERSTANDING YOUR RESULTS
Invalid Result: The test could not tell whether or not you have COVID-19, influenza A (Flu A), or influenza B (Flu B). The test needs to be repeated with a new kit and sample.
Negative Result: The virus from COVID-19, Flu A, and/or Flu B were not detected in the sample. A negative result does not mean it is certain that you do not have COVID-19, Flu A and/or Flu B infection. There is a higher chance of false negative results with antigen tests compared to laboratory-based molecular tests. If you tested negative and continue to experience COVID-19, Flu A and/or Flu B-like symptoms, you should seek follow-up care with your healthcare provider.
All negative results should be treated as presumptive and confirmation with a molecular assay may be necessary. Negative results do not rule out SARS-CoV-2, Flu A, and/or Flu B infection and should not be used as the sole basis for treatment or patient management decisions, including infection control decisions.
Positive Result: The SARS-CoV-2, Flu A and/or Flu B virus(es) were detected in your sample. It is very likely that you have the respective infection(s) and are contagious. Please contact your healthcare provider or your local health authorities and follow local guidelines for self isolation. There is a small chance that this test can give you a positive result that is incorrect (a false positive). Positive results do not rule out bacterial infection or co-infection with other viruses. The agent detected may not be the definite cause of disease.
Includes
Sealed Test Cassettes: 1; Buffer Tubes: 1; Swabs: 1; Tube Holder (on Box): 1; Quick Reference Instructions (QRI): 1.
WARNINGS
Do not use the test if you have had symptoms for more than 4 days or no symptoms at all.
Do not use if any of the test kit contents or packaging is damaged or open.
When collecting a sample, only use the swab provided in the kit.
All test components are single-use. Do not reuse the test cassette, processing solution, or swab.
Testing should be performed in an area with good lighting.
Do not open the test contents until ready for use. If the test cassette is open for an hour or longer, invalid test results may occur.
Do not use this test if you have been vaccinated with the FluMist/FluMist Quadrivalent live intranasal influenza virus vaccine within the last two weeks.
Do not conduct this test if prone to nose bleeds or have a nose injury.
Do not use this test if you are using nasal corticosteroids.
Do not use this test if you are using zinc-based throat sprays.
Remove any piercings from nose before starting the test.
Keep testing kit and kit components away from children and pets before and after use.
Avoid contact with your skin, eyes, nose, or mouth. Do not ingest any kit components. The reagent solution contains harmful chemicals (see table below). If the solution contacts your skin, eyes, nose, or mouth, flush with large amounts of water. If irritation persists, seek medical advice: https://www.poisonhelp.org or 1-800-222-1222.
Chemical Name | Harms (GHS Code) for each ingredient | Concentration
ProClin 300 | Causes skin irritation (H315) , Causes eye irritation (H320) | 0.05%